洁净室与其它厂房有本质上的不同,它是一个空气相对密闭的厂房,一旦发生火灾,彩钢夹芯板芯材的有毒气体不易排除,直接威胁人的健康。Clean room is essentially different from other factories. It is a relative ...
洁净室与其它厂房有本质上的不同,它是一个空气相对密闭的厂房,一旦发生火灾,彩钢夹芯板芯材的有毒气体不易排除,直接威胁人的健康。 Clean room is essentially different from other factories. It is a relatively closed factory with relatively closed air. Once a fire occurs, the toxic gas of color steel sandwich plate core material is not easy to eliminate, which directly threatens people's health. 洁净室建造是一项系统工程,通常是在土建框架主体结构营造的大空间内,采用符合要求的装修材料,根据工艺要求进行分隔、装修成满足各种使用要求的洁净室。洁净室内的污染控制需净化空调专业与自动控制专业共同完成。 Clean room construction is a systematic project, usually in the large space built by the main structure of the civil engineering framework, using the decoration materials that meet the requirements, according to the process requirements for separation and decoration into a clean room to meet the various use requirements.The pollution control of clean room should be completed together by purifying air conditioning major and automatic control major. 洁净室内的隔断墙体对彩钢板有什么技术要求呢? What technical requirement does the clean indoor partition wall have to color steel plate? 随着新标准的贯彻实施,对洁净室彩钢板提出了更高的要求。 With the implementation of the new standard, higher requirements for clean room color steel plate. 洁净室内的隔断墙体采用品质优良的双面复合夹心净化彩钢板、加以玻璃窗隔墙。隔墙须抵达隔热、隔音、防腐、防火、易清洁消毒。彩钢板墙面与空中、彩钢板墙面之间交接处采用半径不小于30mm的环氧树脂喷塑铝合金圆弧处置。彩钢板拼缝应密封处置。密封胶需用进口医用密封胶,不得产生挥发性有毒气体。彩钢板外表涂层、圆弧环氧树脂喷涂资料和拼缝密封资料均须具有抗静电性能,可避免有害颗粒被吸附到墙体外表。彩钢板装置前须试摆。过道隔断墙采用进口氧化铝处置的半高双层钢化玻璃窗(双层玻璃内含可调铝合金百叶)。玻璃厚度为8mm,下缘距地1100mm。区距离离外墙采用12mm喷砂钢化玻璃。 The partition wall of the clean room adopts the good quality double-sided composite sandwich purification color steel plate, and tries the glass window partition wall.The partition wall must reach heat insulation, sound insulation, corrosion prevention, fire prevention, easy to clean and disinfect.Arm aluminum alloy with the radius of no less than 30mm.The color steel plate joint shall be sealed disposed.The sealant shall be imported medical sealant and shall not produce volatile toxic gases.The exterior coating of color steel plate, arc epoxy resin spraying data and seam sealing data must all have anti-static properties to avoid harmful particles from being absorbed to the surface of the wall.Color steel plate device must be tested before the installation.The aisle partition wall adopts semi-high double-layer tempered glass Windows disposed of imported aluminum oxide (with adjustable aluminum alloy blinds).Glass thickness is 8mm and the lower edge is 1100mm from the ground.Sandblasted tempered glass is used 12mm away from the outer wall. |
2021-12-06
2024-03-09
2020-12-22
2020-08-03
2020-08-03